Vibration Test Chamber - VTC

Technical Data Sheet


Temperature Range:
-40℃ + 180℃ ±1℃
-70℃ + 180℃ ±1℃
Humidity Range: 20% to 98%, ±3% RH
Dew Point Range: +4℃ to +85℃
Climate Range: +25℃ to +85℃
Rate of Change of Temperature:
#3℃ / Minute
#5℃ / Minute
#10℃ / Minute
#15℃ / Minute
Interface For Shaker:
False floor with round / rectangular cutout for vertical / slip table integration.
Horizontal and vertical movement of chamber for shaker Integration.

Standard Test Space

Model
No.
Volume
(Liters)
W
(MM)
D
(MM)
H
(MM)
VTC-200200600600600
VTC-500500750750900
VTC-10001000100010001000

*Test Space can be provided as per customer requirement
*Appearance & Design of Chamber may vary depending on the internal dimension
*All performance measured at Room temperature / Ambient of ±25℃ to ±2℃

Download PDFSend Enquiry

Features

PID type controllers OR Dual loop Microprocessor programmer, Touchscreen based control system with ethernet facility, Recorder. Air cooled / Water cooled Semi Hermetic type CFC free refrigeration system.

Performance:
Conform IS 9000, JSS 55555, 50101, IEC 68, MIL- STD-202, 810, 883, DEF-STD-133 Specifications.

Options:
Altitude up-to 100000 feet
Walk-in chambers available on request
Ess chambers available on request